Msi MS-96C8 Series Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Hardware Msi MS-96C8 Series. MSI MS-96C8 Series User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 113
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
i
5500 Master Series
MS-96C8 (V1.X) Server Board
G52-96C81X1
PDF created with pdfFactory Pro trial version www.pdffactory.com
Vista de página 0
1 2 3 4 5 6 ... 112 113

Resumo do Conteúdo

Página 1 - 5500 Master Series

i5500 Master SeriesMS-96C8 (V1.X) Server BoardG52-96C81X1PDF created with pdfFactory Pro trial version www.pdffactory.com

Página 2 - Technical Support

viiiThis page is intentionally left blank.PDF created with pdfFactory Pro trial version www.pdffactory.com

Página 3 - Safety Instructions

B-10MS-96C8 Server Boardis available. So adding a global hot spare greatly increases the level of dataprotection. (One global hot spare is allowed for

Página 4 - Micro-Star International

B-11LSI SAS RAIDFigure 3.2 shows an IM volume configured with a global hot spare disk.8. When the volume has been fully configured, press C and then s

Página 5

B-12MS-96C8 Server Board3.3 Creating a Second IM or IME VolumeThe LSI Logic SAS controllers allow you to configure two IM or IME volumes. If onevolume

Página 6

B-13LSI SAS RAID3.4 Managing Hot SparesYou can create one global hot spare disk to protect the one or two IM/IME volumesdefined on a SAS controller. U

Página 7

B-14MS-96C8 Server Board3.5 Other Configuration TasksThis section explains how to do other tasks related to configuring and maintaining IMand IME volu

Página 8 - CONTENTS

B-15LSI SAS RAIDFollow these steps to delete a selected array:1. Select Delete Array on the Manage Array screen.2. Press Y to delete the array.After a

Página 9

B-16MS-96C8 Server Board4. Integrated Striping OverviewThis section provides an overview of the LSI Logic Integrated Striping (IS) feature.4.1 Introd

Página 10

B-17LSI SAS RAID4.3 IS DescriptionThe IS feature writes data across multiple disks instead of onto one disk.This is accomplished by partitioning each

Página 11 - Getting Started

B-18MS-96C8 Server Board4.4 Integrated Striping FirmwareThis section describes features of the LSI Logic Integrated Striping (IS) firmware.4.4.1 Host

Página 12 - Mainboard Specifications

B-19LSI SAS RAID5. Creating Integrated Striping VolumesThis section describes how to create Integrated Striping (IS) volumes using the LSILogic SAS BI

Página 13 - Onboard Connectors

1-1Getting StartedGetting StartedChapter 1Thank you for choosing the 5500 Master Series (MS-96C8 V1.X), an excellent server board from MSI.Based on th

Página 14 - JBIOS_WP

B-20MS-96C8 Server Board2. Press Enter to go to the Adapter Properties screen, shown in Figure 5.1.3. On the Adapter Properties screen, use the arrow

Página 15 - Hardware Setup

B-21LSI SAS RAIDFigure 5.2 shows an IS volume configured with two drives.6. When the volume has been fully configured, press C and then select Savecha

Página 16 - Quick Components Guide

B-22MS-96C8 Server Board3. On the Adapter Properties screen, use the arrow keys to select RAID Proper-ties and press Enter.4. Continue with step 4 of

Página 17 - Alignment Key

B-23LSI SAS RAIDhave finished creating the volume. You can locate individual disk drives from the SAS Topology screen. To do this,move the cursor to t

Página 18 - CPU & Cooler Installation

MS-96C8 Server Board1-2Mainboard SpecificationsProcessor- 45nm Intel Nehalem processor (up to 95W) in LGA1366 packageSupported QPI- Up to 6.4 GT/sChi

Página 19 - Important

1-3Getting StartedOnboard I/O Back Panel- 1 PS/2 mouse port- 1 PS/2 keyboard port- 2 USB 2.0 ports- 1 serial port- 1 D-Sub VGA port- 2 RJ-45 LAN jacks

Página 20 - Mainboard

MS-96C8 Server Board1-4BATT+USB PortsT: MouseB: Keyboard COM1VGA1JLAN1JLAN2CLR_CMOSJPWR1JPWR3iTEIT8213FSYS_FAN5CPU1_FANJPWR2SATA4SATA2SATA0SATA5SATA3S

Página 21 - 48x2=96 pin

2-1Hardware SetupHardware SetupChapter 2This chapter provides you with the information abouthardware setup procedures. While doing the installation,be

Página 22 - Power Supply

2-2MS-96C8 Server BoardQuick Components GuideBATT+JPWR2, p.2-8CPU0_FAN,p.2-12JPWR3, p.2-8DIMM Slots,p.2-7CPU, p.2-3SYS_FAN4,p.2-12SYS_FAN5,p.2-12DIMM

Página 23 - Back Panel I/O

2-3Hardware SetupImportantOverheatingOverheating will seriously damage the CPU and system. Always make surethe cooling fan can work properly to protec

Página 24 - Connect to 44-pin

2-4MS-96C8 Server Board2.Lift the load lever up and open theload plate.1. Open the load level.CPU & Cooler InstallationWhen you are installing the

Página 25

2-5Hardware Setup6.Cover the load plate onto thepackage.5.Visually inspect if the CPU is seatedwell into the socket. If not, take outthe CPU with pure

Página 26 - Serial Port Connector: COM2

iiCopyright NoticeThe material in this document is the intellectual property of MICRO-STARINTERNATIONAL. We take every care in the preparation of thi

Página 27

2-6MS-96C8 Server Board9.Align the holes on the mainboard withthe heatsink. Push down the cooleruntil its four clips get wedged intothe holes of the m

Página 28 - I2C Bus Connector: JSMBUS1

2-7Hardware SetupMemoryThese DIMM slots are intended for system memory modules.Installing Memory Modules1. Locate the DIMM slots on the mainboard. Fli

Página 29

2-8MS-96C8 Server BoardPower SupplyPIN SIGNAL13 +3.3V14 -12V15 GND16 PS-ON#17 GND18 GND19 GND20 NC21 +5V22 +5V23 +5V24 GNDPIN SIGNAL 1 +3.3V 2 +3.3V 3

Página 30 - Front Panel Connector: JSSI1

2-9Hardware SetupBack Panel I/OLED Color LED State ConditionOff LAN link is not established.Left Orange On (steady state) LAN link is established.On (

Página 31 - Clear CMOS Jumper: CLR_CMOS

2-10MS-96C8 Server BoardConnectorImportantIf you install two IDE devices on the same cable, you must configure thedrives separately to master / slave

Página 32 - PCI Express x4 Slot

2-11Hardware SetupSerial Attached SCSI Connector: MINISAS1, MINISAS2The SAS connector is a new generation serial communication protocol for devicesdes

Página 33 - BIOS Setup

2-12MS-96C8 Server BoardFan Power Connector: CPU0_FAN, CPU1_FAN, SYS_FAN1/2/3/4/5The fan power connectors support system cooling fan with +12V. When c

Página 34 - Entering Setup

2-13Hardware SetupFront USB Connector: JUSB2, JUSB3This connector, compliant with Intel® I/O Connectivity Design Guide, is ideal for con-necting high-

Página 35 - Control Keys

2-14MS-96C8 Server BoardSPI Flash ROM Connector: J2This connector is used to flash SPI flash ROM.Pin Description Pin Description1 +3.3V DUAL 2 +3.3V D

Página 36 - The Menu Bar

2-15Hardware SetupTPM Connector: JTPM1 (Optional)This connector connects to an optional TPM (Trusted Platform Module). Please referto the TPM security

Página 37

iiiSafety Instructions1. Always read the safety instructions carefully.2. Keep this User’s Manual for future reference.3. Keep this equipment away fr

Página 38 - Advanced

2-16MS-96C8 Server BoardFront Panel Connector: JSSI1The mainboard provides one front panel connector for electrical connection to thefront panel switc

Página 39

2-17Hardware SetupJumperClear CMOS Jumper: CLR_CMOSThere is a CMOS RAM onboard that has a power supply from an external battery tokeep the data of sys

Página 40

2-18MS-96C8 Server BoardSlotPCI (Peripheral Component Interconnect) Express SlotThe PCI Express slot supports the PCI Express interface expansion card

Página 41

3-1BIOS SetupChapter 3BIOS SetupThis chapter provides information on the BIOS Setupprogram and allows you to configure the system foroptimum use.You

Página 42

3-2MS-96C8 Server BoardEntering SetupImportant1.The items under each BIOS category described in this chapter are undercontinuous update for better sys

Página 43

3-3BIOS SetupGetting HelpAfter entering the Setup menu, the first menu you will see is the Main Menu.Main MenuThe main menu lists the setup functions

Página 44

3-4MS-96C8 Server BoardThe Menu Bar MainUse this menu for basic system configurations, such as time, date etc. AdvancedUse this menu to set up the ite

Página 45

3-5BIOS SetupMain AMI BIOS, Processor, System MemoryThese items show the firmware and hardware specifications of your system. Readonly. System TimeThi

Página 46

3-6MS-96C8 Server BoardAdvanced CPU ConfigurationPDF created with pdfFactory Pro trial version www.pdffactory.com

Página 47

3-7BIOS Setup C1E SupportWhen the C1E Support (Enhanced Halt Powerdown State) is enabled, the proc-essor will transition to a lower core to bus ratio

Página 48 - Notify BMC FAN Type

ivFCC-B Radio Frequency Interference StatementThis equipment has beentested and found to complywith the limits for a Class Bdigital device, pursuant t

Página 49

3-8MS-96C8 Server Board IDE ConfigurationWith “Configure SATA as ” set to [IDE]With “Configure SATA as ” set to [AHCI] SATA Configuration, SATA#2 Co

Página 50

3-9BIOS Setup Configure SATA assThis setting specifies the operation mode of the onboard SATA drive. Settingoptions: [IDE], [AHCI], [RAID]. Primary/Se

Página 51

3-10MS-96C8 Server Board Hot PlugThis setting enables/disables the hot plug function of the onboard SATA de-vices and only appears when Configure SATA

Página 52 - Boot Settings Configuration

3-11BIOS Setup AHCI Configuration AHCI BIOS SupportThis BIOS feature controls the SATA controller's AHCI (Advanced Host Control-ler Interface) fu

Página 53

3-12MS-96C8 Server Board Event Log Configuration View Event LogPress [Enter] to view the contents of the DMI event log. Clear Event LogWhen this setti

Página 54

3-13BIOS Setup Intel VT-d Configuration Intel VT-dIntel Virtualization Technology for Directed I/O (Intel VT-d) provides the capabil-ity to ensure imp

Página 55

3-14MS-96C8 Server Board IPMI 2.0 Configuration Status of BMC, BMC Firmware VersionThese settings show the status of the BMC (Baseboard ManagementCont

Página 56 - Security

3-15BIOS Setup BMC LAN Configuration Notify BMC IP SourceUse this setting to check the BMC IP source. Current IP Address in BMC, Current Subnet Mask i

Página 57 - CPU Bridge Configuration

3-16MS-96C8 Server Board Temperature Information Fan Speed Information Notify BMC FAN TypeThis setting specifies the BMC fan type.PDF created with pdf

Página 58

3-17BIOS Setup Voltage Information Remote Access Configuration Remote AccessThe setting enables/disables the remote access function. When set to [Enab

Página 59

vWEEE (Waste Electrical and Electronic Equipment) StatementPDF created with pdfFactory Pro trial version www.pdffactory.com

Página 60

3-18MS-96C8 Server Board Flow ControlFlow control is the process of managing the rate of data transmission betweentwo nodes. It’s the process of adjus

Página 61

3-19BIOS Setup TPM DeactivatedWhen the TPM is cleared, all the keys you previously had stored on your vaultwill be lost. You should create an archive

Página 62

3-20MS-96C8 Server BoardBoot Boot Settings ConfigurationPDF created with pdfFactory Pro trial version www.pdffactory.com

Página 63 - Appendix A

3-21BIOS Setup Quick BootEnabling this setting will cause the BIOS power-on self test routine to skip someof its tests during bootup for faster system

Página 64 - Introduction

3-22MS-96C8 Server Board Boot Device Priority 1st Boot Device, 2nd Boot Device, 3rd Boot DeviceThe items allow you to set the sequence of boot devices

Página 65 - BIOS Configuration

3-23BIOS Setup Removable Drives 1st DriveThis setting allows users to set the priority of the removable devices. Firstpress <Enter> to enter the

Página 66 - (1) Create RAID Volume

3-24MS-96C8 Server BoardSecurity Supervisor Password / Change Supervisor PasswordSupervisor Password controls access to the BIOS Setup utility. These

Página 67

3-25BIOS SetupChipset CPU Bridge ConfigurationPDF created with pdfFactory Pro trial version www.pdffactory.com

Página 68

3-26MS-96C8 Server Board Memory FrequencyThis item allows you to select the memory frequency. Memory ModeThis setting specifies the memory mode. North

Página 69

3-27BIOS Setup South Bridge Configuration GbE ControllerThese settings disable/enable the specified LAN controllers. GbE LAN Boot, 82574L OPROMThe ite

Página 70

viPDF created with pdfFactory Pro trial version www.pdffactory.com

Página 71 - (4) Recovery Volume Options

3-28MS-96C8 Server Board ME Subsystem Configuration ME-HECIThis setting enables/disables ME-HECI. Host Embedded Controller Interface(HECI) driver is a

Página 72 - Installing Driver

3-29BIOS SetupExit Save Changes and ExitSave changes to CMOS and exit the Setup Utility. Discard Changes and ExitAbandon all changes and exit the Setu

Página 73

viiiThis page is intentionally left blank.PDF created with pdfFactory Pro trial version www.pdffactory.com

Página 74 - Installing Software

A-1Intel ICH10R SATA RAIDIntel ICH10R SATA RAIDAppendix AThis appendix will assist users in configuring and en-abling RAID functionality on platformsP

Página 75

A-2MS-96C8 Server BoardIntroductionImportantThe least number of hard drives for RAID 0, RAID 1, Recovery or Matrixmode is 2. The least number of hard

Página 76

A-3Intel ICH10R SATA RAIDBIOS ConfigurationAfter the above message shows, press <Ctrl> and <I> keys simultaneously to enterthe RAID Config

Página 77

A-4MS-96C8 Server Board(1) Create RAID Volume1. Select option 1 “Create RAID Volume” and press <Enter> key. The followingscreen appears. Then in

Página 78 - RAID Migration Instructions

A-5Intel ICH10R SATA RAID3. In the Disk field, press <Enter> key and the following screen appears. Use<Space> key to select the disks you

Página 79

A-6MS-96C8 Server Board 6.Then the following screen appears for you to confirm if you are sure tocreate the RAID volume. Press <Y> to continue.

Página 80

A-7Intel ICH10R SATA RAID(2) Delete RAID VolumeHere you can delete the RAID volume, but please be noted that all data on RAIDdrives will be lost.Selec

Página 81

viiPDF created with pdfFactory Pro trial version www.pdffactory.com

Página 82

A-8MS-96C8 Server Board(3) Reset Disks to Non-RAIDSelect option 3 Reset Disks to Non-RAID and press <Enter> to delete the RAIDvolume and remove

Página 83

A-9Intel ICH10R SATA RAID(4) Recovery Volume OptionsSelect option 4 Recovery Volume Options and press <Enter> to change recoveryvolume mode. The

Página 84

A-10MS-96C8 Server BoardInstalling DriverInstall Driver in Windows Server 2008/2003† New Windows Server 2008/2003 InstallationThe following details

Página 85 - Recovery Volume Creation

A-11Intel ICH10R SATA RAID† Existing Windows Server 2008/2003 Driver Installation1. Insert the MSI CD into the CD-ROM drive.2. The CD will auto-run a

Página 86

A-12MS-96C8 Server BoardInstall Intel Matrix Storage ConsoleThe Intel Application Accelerator RAID Edition driver may be used to operate the harddrive

Página 87

A-13Intel ICH10R SATA RAIDThe InstallShield Wizard will begin automatically for installation showed as following:Click on the Next button to proceed t

Página 88 - (8) Select an update policy

A-14MS-96C8 Server BoardAfter reading the license agreement in the following window, click Yes button tocontinue.The window shows the components to be

Página 89 - Degraded RAID Array

A-15Intel ICH10R SATA RAIDOnce the installation is complete, the following window appears.The following window appears to show the Readme File Informa

Página 90

A-16MS-96C8 Server BoardRAID Migration InstructionsImportantA Create from Existing Disk operation will delete all existing data from theadded disk and

Página 91 - Appendix B

A-17Intel ICH10R SATA RAIDCreate RAID Volume from Existing DiskTo create a RAID volume from an existing disk, choose Action --> Create RAIDVolume f

Página 92

viiiCONTENTSCopyright Notice...iiTrademark

Página 93 - 2.1 Introduction

A-18MS-96C8 Server Board(1) Configure VolumeHere you can configure the new RAID volume by entering the volume name, selectingthe RAID level and strip

Página 94 - 2.2 IM Features

A-19Intel ICH10R SATA RAIDexpensive (requiring read-in prior to write, in order tobe able to calculate the correct parity information), orsimilar to R

Página 95 - 2.3 IM/IME Description

A-20MS-96C8 Server Board(3) Select Member Hard Drive(s)Then select the member disk (the target disk) that you wish to use and then click “--->” to

Página 96

A-21Intel ICH10R SATA RAID(4) Specify Volume SizeSpecify the amount of available array space to be used by the new RAID volume. Youmay enter the amoun

Página 97

A-22MS-96C8 Server Board(6) Start MigrationThe migration process may take up to two hours to complete depending on the sizeof the disks being used and

Página 98 - 2.5 Fusion-MPT Support

A-23Intel ICH10R SATA RAIDRecovery Volume CreationA recovery volume can be created using either Basic mode or Advanced mode in theIntel Matrix Storage

Página 99

A-24MS-96C8 Server BoardRecovery Volume in Advanced Mode CreationTo create a recovery volume in Advanced mode, use the following steps:(1) Open the In

Página 100

A-25Intel ICH10R SATA RAID(6) Select a hard drive to be used as the master hard drive for the recovery volume.(7) Select a hard drive to be used as th

Página 101

A-26MS-96C8 Server Board(8) Select an update policy.(9) Select Finish to begin recovery volume creation.PDF created with pdfFactory Pro trial version

Página 102

A-27Intel ICH10R SATA RAIDA RAID 1, RAID 5 or RAID 10 volume is reported as degraded when one of its harddrive members fails or is temporarily disconn

Página 103 - 3.4 Managing Hot Spares

ixAppendix B LSI SAS RAID...B-11. Introduction to Integrated RAID..

Página 104 - 3.5 Other Configuration Tasks

A-28MS-96C8 Server Board5. Exit Intel RAID Option ROM, and then reboot to Windows system.6. When prompted to rebuild the RAID volume, click 'Yes

Página 105

B-1LSI SAS RAIDLSI SAS RAIDAppendix BThis appendix explains how to configure and use thecomponents of the LSI Logic Integrated RAID (IR) soft-ware wit

Página 106 - 4.2 IS Features

B-2MS-96C8 Server BoardThis section provides an overview of the LSI Logic Integrated RAID solution for LSILogic SAS controllers, its features, and its

Página 107 - 4.3 IS Description

B-3LSI SAS RAID2. Integrated Mirroring OverviewThis section provides an overview of the LSI Logic Integrated Mirroring (IM) feature.2.1 IntroductionA

Página 108 - 4.5 Fusion-MPT Support

B-4MS-96C8 Server Board2.2 IM FeaturesLSI Logic Integrated Mirroring and Integrated Mirroring Enhanced support the follow-ing features: Configuration

Página 109 - 5.2 Creating IS Volumes

B-5LSI SAS RAID2.3 IM/IME DescriptionThe LSI Logic Integrated Mirroring (IM) feature supports one or two mirrored volumeson each LSI Logic SAS contro

Página 110

B-6MS-96C8 Server BoardAn IME volume can be configured with up to eight mirrored disks, or seven mirroreddisks and a global hot spare. Figure 2.3 show

Página 111

B-7LSI SAS RAID2.4 Integrated Mirroring FirmwareThis section describes features of the LSI Logic Integrated Mirroring (IM) firmware,which supports up

Página 112 - 5.4 Other Configuration Tasks

B-8MS-96C8 Server Boarddisk. The IM firmware then resynchronizes the mirrored data. The IM firmwareis automatically notified when the failed disk has

Página 113

B-9LSI SAS RAID3. Creating Integrated Mirroring VolumesThis section describes how to create Integrated Mirroring (IM) and Integrated Mirror-ing Enhanc