MSI MS-9652 Manual do Utilizador Página 110

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 134
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 109
Report No 088213R-ITCEP07V04
Page: 107 of 131
11.4. Test Procedure
The EUT and its load are placed on a table that is 0.8 meter above a metal ground plane
measured 1m*1m min. and 0.65mm thick min. And projected beyond the EUT by at least
0.1m on all sides. The length of power cord between the coupling device and the EUT shall
be 2m or less.
For Input and Output AC Power or DC Input and DC Output Power Ports:
The EUT is connected to the power mains through a coupling device that directly couples the
Surge interference signal.
The surge noise shall be applied synchronized to the voltage phase at 0
0
, 90
0
, 180
0
, 270
0
and
the peak value of the a.c. voltage wave. (Positive and negative)
Each of Line-Earth and Line-Line is impressed with a sequence of five surge voltages with
interval of 1 min.
11.5. Deviation from Test Standard
No deviation.
Vista de página 109
1 2 ... 105 106 107 108 109 110 111 112 113 114 115 ... 133 134

Comentários a estes Manuais

Sem comentários