Report No 094061R-ITCEP07V06
Page: 21 of 123
2.3. Measurement Uncertainty
Conducted Emission
The measurement uncertainty is evaluated as ± 2.26 dB.
Impedance Stabilization Network
The measurement uncertainty is evaluated as ± 2.26 dB.
Radiated Emission
The measurement uncertainty is evaluated as ± 3.19 dB.
Electrostatic Discharge
As what is concluded in the document from Note2 of clause 5.4.6.2 of ISO/IEC 17025:
1999[2], the requirements for measurement uncertainty in ESD testing are deemed to have
been satisfied, and the testing is reported in accordance with the relevant ESD standards.
The immunity test signal from the ESD system meet the required specifications in IEC
61000-4-2 through the calibration report with the calibrated uncertainty for the waveform of
voltage and timing as being 1.63 % and 2.76%.
Radiated susceptibility
As what is concluded in the document from Note2 of clause 5.4.6.2 of ISO/IEC 17025:
1999[2], the requirements for measurement uncertainty in RS testing are deemed to have
been satisfied, and the testing is reported in accordance with the relevant RS standards.
The immunity test signal from the RS system meet the required specifications in IEC
61000-4-3 through the calibration for the uniform field strength and monitoring for the test
level with the uncertainty evaluation report for the electrical filed strength as being 2.72 Db.
Electrical fast transient/burst
As what is concluded in the document from Note2 of clause 5.4.6.2 of ISO/IEC 17025:
1999[2], the requirements for measurement uncertainty in EFT/Burst testing are deemed to
have been satisfied, and the testing is reported in accordance with the relevant EFT/Burst
standards. The immunity test signal from the EFT/Burst system meet the required
specifications in IEC 61000-4-4 through the calibration report with the calibrated uncertainty
for the waveform of voltage, frequency and timing as being 1.63 %, 2.8   10-10 and
2.76%.
Surge
As what is concluded in the document from Note2 of clause 5.4.6.2 of ISO/IEC 17025:
1999[2], the requirements for measurement uncertainty in Surge testing are deemed to
have been satisfied, and the testing is reported in accordance with the relevant Surge
standards. The immunity test signal from the Surge system meet the required specifications
in IEC 61000-4-5 through the calibration report with the calibrated uncertainty for the
waveform of voltage and timing as being 1.63 % and 2.76%.