MSI MS-9652 Manual do Utilizador Página 99

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 126
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 98
Report No 094061R-ITCEP07V06
Page: 96 of 123
Product Notebook
Test Item Electrical fast transient/burst
Test Mode Mode 2
Date of Test 2009/04/02 Test Site No.2 Shielded Room
Inject
Line
Polarity
Voltage
kV
Inject
Time
(Second)
Inject
Method
Required
Criteria
Complied
to
Criteria
Result
L+N+PE
±
1kV 60 Direct B B
PASS
LAN
±
0.5kV 60 Clamp B B
PASS
Telec o m
±
0.5Kv 60 Clamp B B
PASS
Note:
The testing performed is from lowest level up to the highest level as required by
standard, but only highest level is shown on the report.
Meet criteria A : Operate as intended during and after the test
Meet criteria B : Operate as intended after the test
Meet criteria C : Loss/Error of function
Additional Information
EUT stopped operation and could / could not be reset by operator at kV of
Line
.
No false alarms or other malfunctions were observed during or after the test.
Vista de página 98
1 2 ... 94 95 96 97 98 99 100 101 102 103 104 ... 125 126

Comentários a estes Manuais

Sem comentários