Report No: 094061R-ITCEP07V06
Page: 23 of 123
2.4. Test Environment
Performed Item Items Required Actual
Temperature (C)
15-35 25
Conducted Emission Humidity (%RH) 25-75 50
Barometric pressure (mbar) 860-1060 950-1000
Temperature (C)
15-35 25
Impedance Stabilization
Network
Humidity (%RH) 25-75 50
Barometric pressure (mbar) 860-1060 950-1000
Temperature (C)
15-35 25
Radiated Emission Humidity (%RH) 25-75 50
Barometric pressure (mbar) 860-1060 950-1000
Temperature (C)
15-35 21
Electrostatic Discharge Humidity (%RH) 30-60 51
Barometric pressure (mbar) 860-1060 950-1000
Temperature (C)
15-35 21
Radiated susceptibility Humidity (%RH) 25-75 51
Barometric pressure (mbar) 860-1060 950-1000
Temperature (C)
15-35 21
Electrical fast
transient/burst
Humidity (%RH) 25-75 51
Barometric pressure (mbar) 860-1060 950-1000
Temperature (C)
15-35 21
Surge Humidity (%RH) 10-75 51
Barometric pressure (mbar) 860-1060 950-1000
Temperature (C)
15-35 21
Conducted susceptibility Humidity (%RH) 25-75 51
Barometric pressure (mbar) 860-1060 950-1000
Temperature (C)
15-35 21
Power frequency magnetic
field
Humidity (%RH) 25-75 51
Barometric pressure (mbar) 860-1060 950-1000
Temperature (C)
15-35 21
Voltage dips and
interruption
Humidity (%RH) 25-75 51
Barometric pressure (mbar) 860-1060 950-1000