Issue Date: 2003-09-25 Page 13 of 42 Report Reference #
E203413-A17-CB-1
IEC 60950
Clause Requirement + Test Result - Remark Verdict
TRF No.: 1950__F UL International Demko A/S TRF originator: FIMKO
2.7 Overcurrent and Earth Fault Protection in Primary Circuits Pass
2.7.1 Basic requirements The building installation is
considered as protection in
Primary Circuits.
Pass
Instructions when protection relies on building
installation
Pass
2.7.2 Faults not covered in 5.3
Pass
2.7.3 Short-circuit backup protection The building installation is
considered as providing short-
circuit protection.
Pass
2.7.4 Number and location of protective devices ...........:
The building installation is
considered as providing short-
circuit protection.
N/A
2.7.5 Protection by several devices
N/A
2.7.6 Warning to service personnel..............................:
N/A
2.8 Safety Interlocks N/A
2.8.1 General principles
N/A
2.8.2 Protection requirements
N/A
2.8.3 Inadvertent reactivation
N/A
2.8.4 Fail-safe operation
N/A
2.8.5 Interlocks with moving parts
N/A
2.8.6 Overriding an interlock
N/A
2.8.7 Switches and relays in interlock systems
N/A
2.8.7.1 Contact gaps (mm) .............................................:
N/A
2.8.7.2 Overload test
N/A
2.8.7.3 Endurance test
N/A
2.8.7.4 Electric strength test (V)
N/A
2.8.8 Mechanical actuators
N/A