Issue Date: 2003-09-25 Page 9 of 25 Report Reference #
E203413-A17-CB-1
IEC 60950
SubClause
Difference + Test Result - Remark Verdict
UL International Demko A/S
Japan - Differences to IEC60950, Third Edition (1999)
1.2.4.101 Addition:
Definition of CLASS 0I EQUIPMENT
N/A
1.2.12.1 Replacement:
FLAMMABILITY CLASSIFICATION OF
MATERIALS:
"The recognition of the burning behaviour of
materials and their ability to extinguish if ignited.
Materials are classified as in 1.2.12.2 to 1.2.12.9,
and 1.2.12.101 when tested in accordance with
annex A"
N/A
1.2.12.101 Addition:
Definition of VTM CLASS MATERIAL
N/A
1.7.101 Addition:Marking for CLASS 0I EQUIPMENT
The following instruction is indicated on the visible
place of the mains plug or the main body:
"Provide an earthing connection"
N/A
1.7.101 The following instruction is indicated on the visible
place on the main body or written in the operating
instructions:
"Provide an earthing connection before the mains
plug is connected to the mains. And, when
disconnecting the earthing connection, be sure to
disconnect after pulling out the mains plug from the
mains."
N/A
2.1.1.1 Replace:
"IEC 60083" by "IEC 60083 or JIS C 8303"
in 2.1.1.1 b)
N/A
2.6.3.1 Add the following after 1st paragraph:
"This also applies to the conductor of lead wire for
protective earthing of CLASS 0I EQUIPMENT"
N/A
2.6.4.1
Replace 2nd sentence in 1st paragraph:
"For CLASS I EQUIPMENT with a DETACHABLE
POWER SUPPLY CORD, the earthing terminal in
the appliance inlet is regarded as the main
protective earthing terminal"
N/A
2.6.5.4 Replace 1st sentence:
"Protective earthing connections of CLASS I
EQUIPMENT shall make earlier and break later
than the supply connections in each of the
following:"
N/A