Issue Date: 2003-09-25 Page 38 of 42 Report Reference #
E203413-A17-CB-1
IEC 60950
Clause Requirement + Test Result - Remark Verdict
TRF No.: 1950__F UL International Demko A/S TRF originator: FIMKO
4.5 TABLE: temperature rise measurements Pass
test voltage (V) ................................................. :
63 HZ,
90 Vac, 2.5hrs, Horizontal / 254
Vac, 2.5hrs, Horizontal / 90
Vac, 2hrs, Vertical / 254 Vac,
2hrs, Vertical
—
t1 (°C) ............................................................. :
--
—
t2 (°C) ............................................................. :
Ambient = 25.7 / 24.5 / 25.3 /
25.0 degree C
—
temperature rise dT of part/at: dT (K) required dT (K)
C1 body (power unit) 37.2 / 42.6 / 36.7 /
41.2
65
L1 coil (power unit) 34.5 / 40.0 / 34.0 /
38.5
65
T1 coil (power unit) 39.5 / 45.5 / 38.6 /
43.7
70
T1 core (power unit) 39.7 / 46.0 / 38.9 /
44.2
70
PWB near IC1 (power unit) 33.3 / 37.5 / 32.7 /
35.9
65
LX coil (power unit) 35.6 /40.0 / 34.6 /
38.0
65
T1 coil 26.0 /29.7 / 26.0 /
28.5
50
Enclosure inside 15.0 /17.8 / 14.5 /
15.9
40
Enclosure outside 9.9 / 11.6 / 9.4 / 10.0 40
temperature rise dT of winding:
R
1
(Ω) R
2
( Ω)
dT (K)
(K)
insulation
class
-- -- -- -- -- --
supplementary information:
Maximum normal load: Connect to computer and transmit data continuously.
Tmra = 40 degree C, the maximum temperature rise is calculated as follows:
Winding components:Transformer - Class A: dTmax = 75K - 10K-(40-25)K = 50 K
Winding components:Transformer - Class B: dTmax = 95K - 10K-(40-25)K = 70 K
Components with:
- maximum absolute temp. of 105 degree C (PWB): dTmax = (105-40)K = 65 K
- when no class of insulation is given, minimum insulation 105 degree C assumed.
- maximum absolute temp. of 80 degree C (Enclosure): dTmax = (80-40)K = 40 K
User Accessible Area:
- material is plastic (70K) dTmx = 70K-(40-25)K = 55K