Issue Date: 2003-09-25 Page 24 of 42 Report Reference #
E203413-A17-CB-1
IEC 60950
Clause Requirement + Test Result - Remark Verdict
TRF No.: 1950__F UL International Demko A/S TRF originator: FIMKO
4.7 Resistance to Fire Pass
4.7.1 Reducing the risk of ignition and spread of flame Method 1: Selection and
application of components and
materials which minimize the
possibility of ignition and
spread of flame.
Pass
4.7.2 Conditions for a fire enclosure
Pass
4.7.2.1 Parts requiring a fire enclosure A fire enclosure covers all
parts.
Pass
4.7.2.2 Parts not requiring a fire enclosure
N/A
4.7.3 Mat erials Pass
4.7.3.1 General See below. Pass
4.7.3.2 Materials for fire enclosures V-1 minimum. Pass
4.7.3.3 Materials for components and other parts outside
fire enclosures
N/A
4.7.3.4
Materials for components and other parts inside fire
enclosures
All internal materials are rated
V-2 or better or are mounted
on a PWB rated V-1 or better.
See Table 1.5.1 for material
information.
Pass
4.7.3.5 Materials for air filter assemblies
N/A
4.7.3.6 Materials used in high-voltage components
N/A
5 ELECTRICAL REQUIREMENTS AND SIMULATED ABNORMAL CONDITIONS Pass