Issue Date: 2003-09-25 Page 17 of 42 Report Reference #
E203413-A17-CB-1
IEC 60950
Clause Requirement + Test Result - Remark Verdict
TRF No.: 1950__F UL International Demko A/S TRF originator: FIMKO
3.1 General Pass
3.1.1 Current rating and overcurrent protection
Pass
3.1.2 Protection against mechanical damage The wires are routed away
from sharp edges and parts
which could damage
insulation.
Pass
3.1.3 Securing of internal wiring The wires are positioned in
such a manner that prevents
excessive strain, loosening of
terminal connections and
damage of conductor
insulation.
Pass
3.1.4 Insulation of conductors Insulation on internal
conductors is considered to be
of adequate quality and
suitable for the application and
the working voltages involved.
All internal wirings are UL
Recognized and rated
minimum 300 V ac.
Pass
3.1.5 Beads and ceramic insulators
N/A
3.1.6 Screws for electrical contact pressure
N/A
3.1.7 Non -metallic materials in electrical connections No contact pressure through
insulating material.
Pass
3.1.8 Self-tapping and spaced thread screws
N/A
3.1.9 Termination of conductors
N/A
10 N pull test
N/A
3.1.10
Sleeving on wiring Not provided. N/A