Issue Date: 2003-09-25 Page 12 of 25 Report Reference #
E203413-A17-CB-1
IEC 60950
SubClause
Difference + Test Result - Remark Verdict
UL International Demko A/S
Norway - Differences to IEC60950, Third Edition (1999)
1.5.8 Due to the IT power system used (see annex V,
figure V.7), capacitors are required to be rated for
the applicable phase-to-phase voltage ( 230 V).
N/A
1.7.2 CLASS I PLUGGABLE EQUIPMENT TYPE A
intended for connection to other equipment or a
communication network where safety relies on
connection to protective earth, require a marking
stating that the equipment must be connected to
an
earthed mains socket-outlet.
N/A
2.2.4 Requirements according to sub-clauses 1.7.2 and
6.1.2.1 apply for this clause.
N/A
2.3.2 Requirements according to sub-clause 6.1.2.1
apply for this clause.
N/A
2.3.3 Requirements according to sub-clause 6.1.2.1
apply for this clause.
N/A
2.3.4 Requirements according to sub-clauses 1.7.2 and
6.1.2.1 apply for this clause.
N/A
2.10.3.1 Due to the IT power distribution system used (see
annex V, figure V.7), the A.C. MAINS SUPPLY
voltage is considered to be equal to the line-to-line
earth fault.
N/A
6.1.2.1 Note 2.
Add the following text between the first and second
paragraph:
If this insulation is solid, including insulation
forming part of a component
, it shall at least consist
of either
- two layers of thin sheet material, each of which
shall pass the electric strength test below, or
- one layer having a distance through insulation of
at least 0.4 mm, which shall pass the electric
strength test below.
N/A