Issue Date: 2003-09-25 Page 19 of 25 Report Reference #
E203413-A17-CB-1
IEC 60950
SubClause
Difference + Test Result - Remark Verdict
UL International Demko A/S
2.6 Units having receptacles for output a.c. power
connectors which are generated from an internal
separately derived source have the grounded
circuit conductor suitably bonded to earth
N/A
2.6.3.3 Capacity of connection between earthing terminal
and parts required to be earthed subject to special
conditions based on the current rating of the circuit
N/A
2.6.3.3 Protective bonding conductors and their terminals
of non-standard constructions (e.g. PWB traces)
evaluated to limited short-circuit test of CSA C22.2
No.4
N/A
2.6.4.1 Field wiring terminals for earthing conductors must
be suitable for wire sizes (gauge) used in US and
Canada
N/A
2.7.1 Data for selection of special external branch circuit
overcurrent devices marked on the appliance
N/A
2.7.1 Standard supply outlets protected by overcurrent
device in accordance with the NEC, and CEC, Part
1
N/A
2.7.1 Overcurrent protection for individual transformers
that distribute power to other units over branch
circuit wiring
N/A
2.7.1 Additional requirements for overcurrent protection
apply to equipment provided with panelboards
N/A
2.7.1 Non -motor-operated equipment requiring special
overcurrent protective device marked with device
rating
N/A
2.10.5.4 Multi-layer winding wire subject to UL wire
requirements in addition to 2.10.5.4 and Annex U
Pass
3.1.1
cable sizes for overcurrent and short circuit
protection
N/A
3.1.1
All interconnecting cables protected against
overcurrent and short circuit
Pass
3.2 Wiring methods permit connection of equipment to
primary power supply in accordance with the NEC
and CEC, Part 1
Pass
3.2.1 Permitted use for flexible cords and plugs
N/A
3.2.1 Flexible cords provided with attachment plug rated
125% of equipment current rating
N/A